Validation Results for MoyaeFhirOphthalmology

Generated Tue Jun 02 00:09:25 UTC 2026, FHIR version 4.0.1 for moyae.fhir.ophthalmology#0.1.0 (canonical = https://fhir.moyae.com (history)). See Errors Only & IP

Quality Checks
Publisher Version:IG Publisher Version: v2.2.8
Publication Code:n/a . PackageId = moyae.fhir.ophthalmology, Canonical = https://fhir.moyae.com
Realm Check for n/a:
  • n/a
Language Info:This IG has no language information
Publication Request:
  • This IG has never been published
  • No publication request found
Supressed Messages:6 Suppressed Issues
Dependency Checks:
PackageVersionFHIRCanonicalWeb BaseComment
.. moyae.fhir.ophthalmology0.1.0R4https://fhir.moyae.com
... hl7.terminology.r47.1.0 MR4http://terminology.hl7.orghttp://terminology.hl7.org/7.1.0
.... hl7.fhir.uv.extensions.r45.2.0 OR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.2.0Latest Release is 5.3.0
... hl7.fhir.uv.extensions.r45.3.0 MR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.3.0
.... hl7.terminology.r47.1.0 MR4http://terminology.hl7.orghttp://terminology.hl7.org/7.1.0 (as above)
... hl7.fhir.us.core6.1.0 OR4http://hl7.org/fhir/us/corehttp://hl7.org/fhir/us/core/STU6.1Latest Release is 9.0.0
.... hl7.terminology.r45.0.0 OR4http://terminology.hl7.orghttp://terminology.hl7.org/5.0.0Latest Release is 7.1.0
.... hl7.fhir.uv.extensions.r41.0.0 OR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/1.0.0Latest Release is 5.3.0
.... hl7.fhir.uv.bulkdata2.0.0 OR4http://hl7.org/fhir/uv/bulkdatahttp://hl7.org/fhir/uv/bulkdata/STU2Latest Release is 3.0.0
.... hl7.fhir.uv.smart-app-launch2.1.0 OR4http://hl7.org/fhir/smart-app-launchhttp://hl7.org/fhir/smart-app-launch/STU2.1Latest Release is 2.2.0
..... hl7.terminology.r45.0.0 OR4http://terminology.hl7.orghttp://terminology.hl7.org/5.0.0 (as above). Latest Release is 7.1.0
.... us.nlm.vsac0.11.0 OR4http://fhir.org/packages/us.nlm.vsachttp://fhir.org/packages/us.nlm.vsacLatest Release is 0.24.0
.... hl7.fhir.uv.sdc3.0.0 OR4http://hl7.org/fhir/uv/sdchttp://hl7.org/fhir/uv/sdc/STU3Latest Release is 4.0.0
..... hl7.fhir.r4.examples4.0.1 OR4http://hl7.org/fhirhttp://hl7.org/fhir/R4Latest Release is 5.0.0
.... us.cdc.phinvads0.12.0 MR4http://fhir.org/packages/us.cdc.phinvadshttp://fhir.org/packages/us.cdc.phinvads
.... ihe.formatcode.fhir1.1.0 OR4https://profiles.ihe.net/fhir/ihe.formatcode.fhirhttps://profiles.ihe.net/fhir/ihe.formatcode.fhir/1.1.0Latest Release is 1.5.0
Templates: fhir.base.template#current
Related IGs:n/a
Dependent IGs:no references
Global Profiles:(none declared)
Terminology Server(s):https://tx.fhir.org/r4 (details)
HTA Analysis:Non-HL7 Igs are exempt from terminology dependency analysis
R5 Dependencies:(none)
Draft Dependencies:
Modifier Extensions:(none)
Previous Version Comparison: Unable to compare with previous version: Unable to find version history at https://fhir.moyae.com (Problem #1 with package-list.json at https://fhir.moyae.com: Not Found)
IPA Comparison: n/a
IPS Comparison: n/a
Validation Flags: On: autoLoad; Off: hintAboutNonMustSupport, anyExtensionsAllowed, checkAggregation, showReferenceMessages, noExperimentalContent, displayWarnings
Summary: errors = 3, warn = 23, info = 21, broken links = 0, pinned = n/a.
FilenameErrorsWarningsHints
Build Errors140
/home/runner/work/FHIR/FHIR/fsh-generated/includes/fsh-link-references000
/home/runner/work/FHIR/FHIR/fsh-generated/includes/menu000
/home/runner/work/FHIR/FHIR/fsh-generated/resources/CodeSystem-moyae-is-cc-cs000
/home/runner/work/FHIR/FHIR/fsh-generated/resources/Encounter-example-encounter001
/home/runner/work/FHIR/FHIR/fsh-generated/resources/ImplementationGuide-moyae.fhir.ophthalmology010
/home/runner/work/FHIR/FHIR/fsh-generated/resources/Observation-Example-MoyaeIOP-RightEye110
/home/runner/work/FHIR/FHIR/fsh-generated/resources/Observation-Example-MoyaeRefraction-Manifest110
/home/runner/work/FHIR/FHIR/fsh-generated/resources/Observation-Example-MoyaeVisualAcuity-Corrected010
/home/runner/work/FHIR/FHIR/fsh-generated/resources/Patient-example-patient000
/home/runner/work/FHIR/FHIR/fsh-generated/resources/Practitioner-example-doctor000
/home/runner/work/FHIR/FHIR/fsh-generated/resources/StructureDefinition-moyae-intraocular-pressure005
/home/runner/work/FHIR/FHIR/fsh-generated/resources/StructureDefinition-moyae-refraction000
/home/runner/work/FHIR/FHIR/fsh-generated/resources/StructureDefinition-moyae-vision-prescription000
/home/runner/work/FHIR/FHIR/fsh-generated/resources/StructureDefinition-moyae-visual-acuity000
/home/runner/work/FHIR/FHIR/fsh-generated/resources/ValueSet-moyae-body-site-eye-vs012
/home/runner/work/FHIR/FHIR/fsh-generated/resources/ValueSet-moyae-eye-code-vs030
/home/runner/work/FHIR/FHIR/fsh-generated/resources/ValueSet-moyae-laterality-vs030
/home/runner/work/FHIR/FHIR/fsh-generated/resources/ValueSet-moyae-refraction-method-vs012
/home/runner/work/FHIR/FHIR/fsh-generated/resources/ValueSet-moyae-visual-acuity-code-vs012
/home/runner/work/FHIR/FHIR/fsh-generated/resources/ValueSet-vision-base-vs010
/home/runner/work/FHIR/FHIR/fsh-generated/resources/ValueSet-vision-eyes-vs010
/home/runner/work/FHIR/FHIR/fsh-generated/resources/ValueSet-vision-prescription-product-vs013
/home/runner/work/FHIR/FHIR/fsh-generated/resources/ValueSet-vision-prescription-status-vs012
/home/runner/work/FHIR/FHIR/fsh-generated/resources/VisionPrescription-Example-MoyaeVisionPrescription-Active012
/home/runner/work/FHIR/FHIR/fsh-generated/resources/VisionPrescription-Example-MoyaeVisionPrescription-Draft012
/home/runner/work/FHIR/FHIR/input/pagecontent/index000
/home/runner/work/FHIR/FHIR/input/pagecontent/relationships000
/home/runner/work/FHIR/FHIR/temp/pages/_includes/artifacts000
/home/runner/work/FHIR/FHIR/template/config000
/home/runner/work/FHIR/FHIR/template/config/_config000

n/a Show Validation Information

ImplementationGuide​.definition​.parameter[27]​.valueerrorSupressed messages file is not using the new format (see https://confluence.hl7.org/display/FHIR/Implementation+Guide+Parameters)
1warningThe HTML fragment 'ip-statements.xhtml' is not included anywhere in the produced implementation guide
2warningAn HTML fragment from the set [cross-version-analysis.xhtml, cross-version-analysis-inline.xhtml] is not included anywhere in the produced implementation guide
3warningAn HTML fragment from the set [dependency-table.xhtml, dependency-table-short.xhtml, dependency-table-nontech.xhtml] is not included anywhere in the produced implementation guide
4warningThe HTML fragment 'globals-table.xhtml' is not included anywhere in the produced implementation guide

fsh-generated/includes/fsh-link-references.md Show Validation Information (0)


fsh-generated/includes/menu.xml Show Validation Information (0)


fsh-generated/resources/CodeSystem-moyae-is-cc-cs.json Show Validation Information (1)


fsh-generated/resources/Encounter-example-encounter.json Show Validation Information (1)

PathSeverityMessageValidating
Encounter.class (l5/c4)informationReference to draft CodeSystem http://terminology.hl7.org/CodeSystem/v3-ActCode|2018-08-12 MSG_DRAFTEncounter

fsh-generated/resources/ImplementationGuide-moyae.fhir.ophthalmology.json Show Validation Information (1)

PathSeverityMessageValidating
ImplementationGuide​.dependsOn[2] (l1​/c2546)warningThe ImplementationGuide uses package hl7.fhir.us.core#6.1.0 released on 2023-06-30, but the most recent appropriate version is 9.0.0. This reference is getting old and the more recent version should be considered IG_DEPENDENCY_VERSION_WARNING_OLD--

fsh-generated/resources/Observation-Example-MoyaeIOP-RightEye.json Show Validation Information (1)

PathSeverityMessageValidating
Observation​.bodySite​.coding[0]​.display (l41​/c4)errorWrong Display Name 'Right eye' for http://snomed.info/sct#1290030002. Valid display is one of 2 choices: 'Disorder of left eye proper (disorder)' (en) or 'Disorder of left eye proper' (en) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_ofMoyae Intraocular Pressure Observation
Observation (l1/c2)warningBest Practice Recommendation: In general, all observations should have a performer All_observations_should_have_a_performer--

fsh-generated/resources/Observation-Example-MoyaeRefraction-Manifest.json Show Validation Information (1)

PathSeverityMessageValidating
Observation​.component[1]​.code​.coding[0]​.display (l60​/c8)errorWrong Display Name 'Subjective / Manifest refraction (procedure)' for http://snomed.info/sct#397277005. Valid display is one of 4 choices: 'Subjective refraction (procedure)' (en), 'Subjective refraction' (en), 'M-Manifest refraction' (en) or 'Manifest refraction' (en) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_ofMoyae Refraction Observation (current shape)
Observation (l1/c2)warningBest Practice Recommendation: In general, all observations should have a performer All_observations_should_have_a_performer--

fsh-generated/resources/Observation-Example-MoyaeVisualAcuity-Corrected.json Show Validation Information (1)

PathSeverityMessageValidating
Observation (l1/c2)warningBest Practice Recommendation: In general, all observations should have a performer All_observations_should_have_a_performer--

fsh-generated/resources/Patient-example-patient.json Show Validation Information (1)


fsh-generated/resources/Practitioner-example-doctor.json Show Validation Information (1)


fsh-generated/resources/StructureDefinition-moyae-intraocular-pressure.json Show Validation Information (1)

PathSeverityMessageValidating
StructureDefinition​.snapshot​.element[4]​.binding​.extension[0] (l1​/c81369)informationThe extension http://hl7.org/fhir/StructureDefinition/elementdefinition-maxValueSet|5.3.0 is deprecated with the note: 'Use additionalBinding extension or element instead' MSG_DEPENDS_ON_DEPRECATED_NOTEStructureDefinition
StructureDefinition​.differential​.element[5]​.slicing​.discriminator[0] (l1​/c254465)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.differential​.element[23]​.slicing​.discriminator[0] (l1​/c256665)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.snapshot​.element[24]​.slicing​.discriminator[0] (l1​/c107885)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--
StructureDefinition​.snapshot​.element[102]​.slicing​.discriminator[0] (l1​/c210640)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED--

fsh-generated/resources/StructureDefinition-moyae-refraction.json Show Validation Information (1)


fsh-generated/resources/StructureDefinition-moyae-vision-prescription.json Show Validation Information (1)


fsh-generated/resources/StructureDefinition-moyae-visual-acuity.json Show Validation Information (1)


fsh-generated/resources/ValueSet-moyae-body-site-eye-vs.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet​.compose​.include[0]​.concept[0] (l1​/c1640)informationWrong Display Name 'Right eye' for http://snomed.info/sct#1290030002. Valid display is one of 2 choices: 'Disorder of left eye proper (disorder)' (en) or 'Disorder of left eye proper' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet​.compose​.include[0]​.concept[1] (l1​/c1683)informationWrong Display Name 'Left eye' for http://snomed.info/sct#1290031003. Valid display is one of 2 choices: 'Structure of left eye proper' (en) or 'Structure of left eye proper (body structure)' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet (l1/c1688)warningPublished value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present --

fsh-generated/resources/ValueSet-moyae-eye-code-vs.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet​.compose​.include[0]​.concept[0] (l1​/c1657)warningThe concept '8966001' has a status of inactive and its use should be reviewed (from https://tx.fhir.org/r4, see log, or see the servers logic) INACTIVE_CONCEPT_FOUND--
ValueSet​.compose​.include[0]​.concept[1] (l1​/c1699)warningThe concept '18944008' has a status of inactive and its use should be reviewed (from https://tx.fhir.org/r4, see log) INACTIVE_CONCEPT_FOUND--
ValueSet (l1/c1704)warningPublished value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present --

fsh-generated/resources/ValueSet-moyae-laterality-vs.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet​.compose​.include[0]​.concept[0] (l1​/c1630)warningThe concept '419465000' has a status of inactive and its use should be reviewed (from https://tx.fhir.org/r4, see log, or see the servers logic) INACTIVE_CONCEPT_FOUND--
ValueSet​.compose​.include[0]​.concept[1] (l1​/c1679)warningThe concept '419161000' has a status of inactive and its use should be reviewed (from https://tx.fhir.org/r4, see log) INACTIVE_CONCEPT_FOUND--
ValueSet (l1/c1684)warningPublished value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present --

fsh-generated/resources/ValueSet-moyae-refraction-method-vs.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet​.compose​.include[0]​.concept[0] (l1​/c2261)informationWrong Display Name 'Subjective / Manifest refraction (procedure)' for http://snomed.info/sct#397277005. Valid display is one of 4 choices: 'Subjective refraction (procedure)' (en), 'Subjective refraction' (en), 'M-Manifest refraction' (en) or 'Manifest refraction' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet.compose.include[0] (l1/c2500)informationThis SNOMED-CT based include has some concepts with semantic tags (FSN terms) and some without (preferred terms) - check that this is what is intended (examples for FSN: [Subjective / Manifest refraction (procedure), Cycloplegic refraction (procedure), Overrefraction (procedure)] and examples for no FSN: [Autorefractor, Best Corrected Visual Acuity]) VALUESET_CONCEPT_DISPLAY_SCT_TAG_MIXED--
ValueSet (l1/c2503)warningPublished value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present --

fsh-generated/resources/ValueSet-moyae-visual-acuity-code-vs.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet​.compose​.include[0]​.concept[3] (l1​/c2174)informationWrong Display Name 'Retina VA' for http://snomed.info/sct#363983007. Valid display is one of 3 choices: 'Visual acuity' (en), 'Visual acuity (observable entity)' (en) or 'VA - Visual acuity' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet.compose.include[0] (l1/c2176)informationThis SNOMED-CT based include has some concepts with semantic tags (FSN terms) and some without (preferred terms) - check that this is what is intended (examples for FSN: [Corrected visual acuity (observable entity)] and examples for no FSN: [Uncorrected visual acuity, Refraction, Retina VA]) VALUESET_CONCEPT_DISPLAY_SCT_TAG_MIXED--
ValueSet (l1/c2179)warningPublished value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present --

fsh-generated/resources/ValueSet-vision-base-vs.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet (l1/c2087)warningPublished value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present --

fsh-generated/resources/ValueSet-vision-eyes-vs.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet (l1/c1772)warningPublished value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present --

fsh-generated/resources/ValueSet-vision-prescription-product-vs.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet.compose.include[0]informationPinned the version of http://terminology.hl7.org/CodeSystem/ex-visionprescriptionproduct to 4.0.1 from choices of 0.1.0 (hl7.terminology.r4#5.0.0), 1.0.1 (hl7.terminology.r4#7.1.0) PIN_VERSION--
ValueSet​.compose​.include[0]​.concept[0] (l1​/c1917)informationReference to draft CodeSystem http://terminology.hl7.org/CodeSystem/ex-visionprescriptionproduct|4.0.1 MSG_DRAFT--
ValueSet​.compose​.include[0]​.concept[0] (l1​/c1917)informationWrong Display Name 'Glasses lens' for http://terminology.hl7.org/CodeSystem/ex-visionprescriptionproduct#lens. Valid display is 'Lens' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT_VER--
ValueSet (l1/c1966)warningPublished value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present --

fsh-generated/resources/ValueSet-vision-prescription-status-vs.json Show Validation Information (1)

PathSeverityMessageValidating
ValueSet​.compose​.include[0]​.concept[0] (l1​/c2439)informationWrong Display Name 'Draft (used for in-exam measurement)' for http://hl7.org/fhir/fm-status#draft. Valid display is 'Draft' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet​.compose​.include[0]​.concept[1] (l1​/c2498)informationWrong Display Name 'Active (signed prescription)' for http://hl7.org/fhir/fm-status#active. Valid display is 'Active' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code VALUESET_CODE_CONCEPT_HINT--
ValueSet (l1/c2603)warningPublished value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present --

fsh-generated/resources/VisionPrescription-Example-MoyaeVisionPrescription-Active.json Show Validation Information (1)

PathSeverityMessageValidating
VisionPrescription​.identifier[0]​.system (l11​/c63)warningNo definition could be found for URL value 'https://moyae.com/vision-prescription-status' Type_Specific_Checks_DT_URL_ResolveMoyae Vision Prescription (current shape)
VisionPrescription​.lensSpecification[0]​.product (l17​/c8)informationReference to draft CodeSystem http://terminology.hl7.org/CodeSystem/ex-visionprescriptionproduct|4.0.1 MSG_DRAFTMoyae Vision Prescription (current shape)
VisionPrescription​.lensSpecification[1]​.product (l42​/c8)informationReference to draft CodeSystem http://terminology.hl7.org/CodeSystem/ex-visionprescriptionproduct|4.0.1 MSG_DRAFTMoyae Vision Prescription (current shape)

fsh-generated/resources/VisionPrescription-Example-MoyaeVisionPrescription-Draft.json Show Validation Information (1)

PathSeverityMessageValidating
VisionPrescription​.identifier[0]​.system (l11​/c63)warningNo definition could be found for URL value 'https://moyae.com/vision-prescription-status' Type_Specific_Checks_DT_URL_ResolveMoyae Vision Prescription (current shape)
VisionPrescription​.lensSpecification[0]​.product (l17​/c8)informationReference to draft CodeSystem http://terminology.hl7.org/CodeSystem/ex-visionprescriptionproduct|4.0.1 MSG_DRAFTMoyae Vision Prescription (current shape)
VisionPrescription​.lensSpecification[1]​.product (l43​/c8)informationReference to draft CodeSystem http://terminology.hl7.org/CodeSystem/ex-visionprescriptionproduct|4.0.1 MSG_DRAFTMoyae Vision Prescription (current shape)

input/pagecontent/index.md Show Validation Information (0)


input/pagecontent/relationships.md Show Validation Information (0)


temp/pages/_includes/artifacts.xml Show Validation Information (0)


template/config Show Validation Information (0)


template/config/_config.yml Show Validation Information (0)

Suppressed Messages (Warnings, hints, broken links)

?pub-msg-2?

Errors sorted by type


All_observations_should_have_a_performer

fsh-generated/resources/Observation-Example-MoyaeIOP-RightEye.jsonBest Practice Recommendation: In general, all observations should have a performer--
fsh-generated/resources/Observation-Example-MoyaeRefraction-Manifest.jsonBest Practice Recommendation: In general, all observations should have a performer--
fsh-generated/resources/Observation-Example-MoyaeVisualAcuity-Corrected.jsonBest Practice Recommendation: In general, all observations should have a performer--

Display_Name_for__should_be_one_of__instead_of

fsh-generated/resources/Observation-Example-MoyaeIOP-RightEye.jsonWrong Display Name 'Right eye' for http://snomed.info/sct#1290030002. Valid display is one of 2 choices: 'Disorder of left eye proper (disorder)' (en) or 'Disorder of left eye proper' (en) (for the language(s) 'en-US')Moyae Intraocular Pressure Observation
fsh-generated/resources/Observation-Example-MoyaeRefraction-Manifest.jsonWrong Display Name 'Subjective / Manifest refraction (procedure)' for http://snomed.info/sct#397277005. Valid display is one of 4 choices: 'Subjective refraction (procedure)' (en), 'Subjective refraction' (en), 'M-Manifest refraction' (en) or 'Manifest refraction' (en) (for the language(s) 'en-US')Moyae Refraction Observation (current shape)

IG_DEPENDENCY_VERSION_WARNING_OLD

fsh-generated/resources/ImplementationGuide-moyae.fhir.ophthalmology.jsonThe ImplementationGuide uses package hl7.fhir.us.core#6.1.0 released on 2023-06-30, but the most recent appropriate version is 9.0.0. This reference is getting old and the more recent version should be considered--

INACTIVE_CONCEPT_FOUND

fsh-generated/resources/ValueSet-moyae-eye-code-vs.jsonThe concept '8966001' has a status of inactive and its use should be reviewed--
fsh-generated/resources/ValueSet-moyae-eye-code-vs.jsonThe concept '18944008' has a status of inactive and its use should be reviewed--
fsh-generated/resources/ValueSet-moyae-laterality-vs.jsonThe concept '419465000' has a status of inactive and its use should be reviewed--
fsh-generated/resources/ValueSet-moyae-laterality-vs.jsonThe concept '419161000' has a status of inactive and its use should be reviewed--

MSG_DEPENDS_ON_DEPRECATED_NOTE

fsh-generated/resources/StructureDefinition-moyae-intraocular-pressure.jsonThe extension http://hl7.org/fhir/StructureDefinition/elementdefinition-maxValueSet|5.3.0 is deprecated with the note: 'Use additionalBinding extension or element instead'StructureDefinition

MSG_DRAFT

fsh-generated/resources/Encounter-example-encounter.jsonReference to draft CodeSystem http://terminology.hl7.org/CodeSystem/v3-ActCode|2018-08-12Encounter
fsh-generated/resources/ValueSet-vision-prescription-product-vs.jsonReference to draft CodeSystem http://terminology.hl7.org/CodeSystem/ex-visionprescriptionproduct|4.0.1--
fsh-generated/resources/VisionPrescription-Example-MoyaeVisionPrescription-Active.jsonReference to draft CodeSystem http://terminology.hl7.org/CodeSystem/ex-visionprescriptionproduct|4.0.1Moyae Vision Prescription (current shape)
fsh-generated/resources/VisionPrescription-Example-MoyaeVisionPrescription-Active.jsonReference to draft CodeSystem http://terminology.hl7.org/CodeSystem/ex-visionprescriptionproduct|4.0.1Moyae Vision Prescription (current shape)
fsh-generated/resources/VisionPrescription-Example-MoyaeVisionPrescription-Draft.jsonReference to draft CodeSystem http://terminology.hl7.org/CodeSystem/ex-visionprescriptionproduct|4.0.1Moyae Vision Prescription (current shape)
fsh-generated/resources/VisionPrescription-Example-MoyaeVisionPrescription-Draft.jsonReference to draft CodeSystem http://terminology.hl7.org/CodeSystem/ex-visionprescriptionproduct|4.0.1Moyae Vision Prescription (current shape)

PIN_VERSION

fsh-generated/resources/ValueSet-vision-prescription-product-vs.jsonPinned the version of http://terminology.hl7.org/CodeSystem/ex-visionprescriptionproduct to 4.0.1 from choices of 0.1.0 (hl7.terminology.r4#5.0.0), 1.0.1 (hl7.terminology.r4#7.1.0)--

SD_PATH_SLICING_DEPRECATED

fsh-generated/resources/StructureDefinition-moyae-intraocular-pressure.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
fsh-generated/resources/StructureDefinition-moyae-intraocular-pressure.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
fsh-generated/resources/StructureDefinition-moyae-intraocular-pressure.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--
fsh-generated/resources/StructureDefinition-moyae-intraocular-pressure.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)--

Type_Specific_Checks_DT_URL_Resolve

fsh-generated/resources/VisionPrescription-Example-MoyaeVisionPrescription-Active.jsonNo definition could be found for URL value 'https://moyae.com/vision-prescription-status'Moyae Vision Prescription (current shape)
fsh-generated/resources/VisionPrescription-Example-MoyaeVisionPrescription-Draft.jsonNo definition could be found for URL value 'https://moyae.com/vision-prescription-status'Moyae Vision Prescription (current shape)

VALUESET_CODE_CONCEPT_HINT

fsh-generated/resources/ValueSet-moyae-body-site-eye-vs.jsonWrong Display Name 'Right eye' for http://snomed.info/sct#1290030002. Valid display is one of 2 choices: 'Disorder of left eye proper (disorder)' (en) or 'Disorder of left eye proper' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
fsh-generated/resources/ValueSet-moyae-body-site-eye-vs.jsonWrong Display Name 'Left eye' for http://snomed.info/sct#1290031003. Valid display is one of 2 choices: 'Structure of left eye proper' (en) or 'Structure of left eye proper (body structure)' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
fsh-generated/resources/ValueSet-moyae-refraction-method-vs.jsonWrong Display Name 'Subjective / Manifest refraction (procedure)' for http://snomed.info/sct#397277005. Valid display is one of 4 choices: 'Subjective refraction (procedure)' (en), 'Subjective refraction' (en), 'M-Manifest refraction' (en) or 'Manifest refraction' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
fsh-generated/resources/ValueSet-moyae-visual-acuity-code-vs.jsonWrong Display Name 'Retina VA' for http://snomed.info/sct#363983007. Valid display is one of 3 choices: 'Visual acuity' (en), 'Visual acuity (observable entity)' (en) or 'VA - Visual acuity' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
fsh-generated/resources/ValueSet-vision-prescription-status-vs.jsonWrong Display Name 'Draft (used for in-exam measurement)' for http://hl7.org/fhir/fm-status#draft. Valid display is 'Draft' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--
fsh-generated/resources/ValueSet-vision-prescription-status-vs.jsonWrong Display Name 'Active (signed prescription)' for http://hl7.org/fhir/fm-status#active. Valid display is 'Active' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--

VALUESET_CODE_CONCEPT_HINT_VER

fsh-generated/resources/ValueSet-vision-prescription-product-vs.jsonWrong Display Name 'Glasses lens' for http://terminology.hl7.org/CodeSystem/ex-visionprescriptionproduct#lens. Valid display is 'Lens' (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code--

VALUESET_CONCEPT_DISPLAY_SCT_TAG_MIXED

fsh-generated/resources/ValueSet-moyae-refraction-method-vs.jsonThis SNOMED-CT based include has some concepts with semantic tags (FSN terms) and some without (preferred terms) - check that this is what is intended (examples for FSN: [Subjective / Manifest refraction (procedure), Cycloplegic refraction (procedure), Overrefraction (procedure)] and examples for no FSN: [Autorefractor, Best Corrected Visual Acuity])--
fsh-generated/resources/ValueSet-moyae-visual-acuity-code-vs.jsonThis SNOMED-CT based include has some concepts with semantic tags (FSN terms) and some without (preferred terms) - check that this is what is intended (examples for FSN: [Corrected visual acuity (observable entity)] and examples for no FSN: [Uncorrected visual acuity, Refraction, Retina VA])--