Moyae Ophthalmology FHIR Implementation Guide
0.1.0 - ci-build
Moyae Ophthalmology FHIR Implementation Guide - Local Development build (v0.1.0) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions
| Official URL: https://moyae.com/is-cc | Version: 0.1.0 | |||
| Active as of 2026-06-02 | Computable Name: MoyaeIsCcCS | |||
Moyae-defined CodeSystem carrying the single concept cc ("with correction"). Used on Observation.component.code in MoyaeVisualAcuity and MoyaeRefraction to indicate whether the patient was wearing their habitual correction (glasses or contacts) when the measurement was taken.
SNOMED CT's 419775003 (Best Corrected Visual Acuity) was considered but is more specific than what Moyae needs — cc=true should also apply when a non-best correction was worn.
This Code system is referenced in the content logical definition of the following value sets: