Moyae Ophthalmology FHIR Implementation Guide
0.1.0 - ci-build
Moyae Ophthalmology FHIR Implementation Guide - Local Development build (v0.1.0) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions
| Active as of 2026-06-02 |
<CodeSystem xmlns="http://hl7.org/fhir">
<id value="moyae-is-cc-cs"/>
<text>
<status value="generated"/>
<div xmlns="http://www.w3.org/1999/xhtml"><p class="res-header-id"><b>Generated Narrative: CodeSystem moyae-is-cc-cs</b></p><a name="moyae-is-cc-cs"> </a><a name="hcmoyae-is-cc-cs"> </a><p>This case-sensitive code system <code>https://moyae.com/is-cc</code> defines the following code:</p><table class="codes"><tr><td style="white-space:nowrap"><b>Code</b></td><td><b>Display</b></td><td><b>Definition</b></td></tr><tr><td style="white-space:nowrap">cc<a name="moyae-is-cc-cs-cc"> </a></td><td>with correction</td><td>The observation was made while the patient was wearing their habitual correction (glasses or contact lenses).</td></tr></table></div>
</text>
<url value="https://moyae.com/is-cc"/>
<version value="0.1.0"/>
<name value="MoyaeIsCcCS"/>
<title value="Moyae 'with correction' Code System"/>
<status value="active"/>
<experimental value="false"/>
<date value="2026-06-02T00:07:33+00:00"/>
<publisher value="Moyae, Inc."/>
<contact>
<name value="Moyae, Inc."/>
<telecom>
<system value="url"/>
<value value="https://moyae.com"/>
</telecom>
<telecom>
<system value="email"/>
<value value="partnerships@moyae.com"/>
</telecom>
</contact>
<contact>
<name value="Moyae, Inc."/>
<telecom>
<system value="url"/>
<value value="https://moyae.com"/>
</telecom>
<telecom>
<system value="email"/>
<value value="partnerships@moyae.com"/>
</telecom>
</contact>
<description
value="Moyae-defined CodeSystem carrying the single concept `cc` ("with correction"). Used on `Observation.component.code` in MoyaeVisualAcuity and MoyaeRefraction to indicate whether the patient was wearing their habitual correction (glasses or contacts) when the measurement was taken.
SNOMED CT's `419775003` (Best Corrected Visual Acuity) was considered but is more specific than what Moyae needs — `cc=true` should also apply when a non-best correction was worn."/>
<caseSensitive value="true"/>
<content value="complete"/>
<count value="1"/>
<concept>
<code value="cc"/>
<display value="with correction"/>
<definition
value="The observation was made while the patient was wearing their habitual correction (glasses or contact lenses)."/>
</concept>
</CodeSystem>